ALARM ZONES CONFIGURATION
PROGRAM ZONE 1 E/E DELAY
ZONE 3 FUNCTION MODE
ZONA 4 FUNCTION MODE
ALARM ZONES CONTROL
ARM ZONES
DISARM ZONES
DEACTIVATE ACOUSTIC ALERT.
Ends the acoustic alert.
The system is not disarmed, and continues to emit alarms if
anything is detected by the sensors.
DEACTIVATE ACOUSTIC ALERT AND DISARM
SYSTEM
The system is disarmed and the acoustic alert ends.
To reactivate the alarms, the system must be armed again.
KEY SEQUENCE:
Parameters:
- Master Code: 1234
- AB: A-B Keys
- Zone Number: 1, 2, 3 or 4
- Function Mode:
- 0 : Normally Open
- 1: Normally Closed
- Timing:
- 000 : Instant
- 001...127
- Time:
- * : Seconds
- # : Minutes
KEY SEQUENCE:
Parameters:
- Master Code: 1234
- AB5: A-B-5 Keys
- RelayNumber: 1, 2, 3, 4, 5
- Timing:
- 001...127
- Time:
- * : Seconds
- # : Minutes
Pag 34
Normal Mode
24 Hour Mode
Normal Mode
24 Hour Mode
FUNCTION MODE AND ZONE TIMINGS
Master Code + AB + ZoneNumber + Func.Mode + Timing +Time
Examples:
1234 AB 1 000 0 *
Zone 1 will be normally open type. It is timed to go off instantly.
1234 AB 2 0 060 *
Zone 2 will be normally open type. It is timed to go off with a delay when sensor activity is
detected for 60 seconds.
1234A B 3 1 001 #
Zone 3 will be normally closed type. It is timed to go off with a delay when sensor activity is
detected for 1 minute.
RELAY TIMINGS
Master Code + AB5 + RelayNumber (1-5) + Timing (000..127) + Time
Examples:
1234 AB 5 3 127 #
The third monodecoder relay stays active for 127 minutes or until deactivated with the
monitor keypad.
The fifth monodecoder relay changes status every time the relay is activated from the «F»
button, or by Tamper circuit activaction (depending on the function programmed in
multifunction button «F»).
KEY SEQUENCE
Master Code + AB + 9 + Time (00..99)
Master Code + AB + A + 0
Master Code + AB + A + 1
Master Code + AB + B + 0
Master Code + AB + B + 1
Master Code + AA
Master Code + BB
Master Code+ *#
Master Code + BB
EXAMPLE
1234AB945
1234ABA0
1234ABA1
1234ABB0
1234ABB1
1234AA
1234BB
1234*#
1234BB