Kits EVOLUTION
Kits EVOLUTION
Arm and Disarm Alarm Zones
* This option lets you arm or disarm the Alarm Zones (up to 4) in the system.
- System Armed: Alarms detection system active.
The system sets off the alarm, generating the corresponding alerts (acoustic alerts, guard unit alert,
ARC..) when activity is detected in any of the "Alarm Zones".
Arming is usually done when entering or leaving the home.
- System Disarmed : Alarms detection system deactivated.
The system does NOT set off any alarms when activity is detected in any of the "Alarm Zones".
Disarming is usually done when the user is at home.
An arming/disarming code must be entered via the telephone keypad to Arm or Disarm the
system.
ACTION
ARM ZONES
DISARM ZONES
The default Master Code is «1234». The Master Code can be changed for greater security.
Please consult the «Change Master Code» section.
When the alarms system is being armed, the monitor informs on the status of each alarm zone, by means of
acoustic alerts and luminous indicators. (See section «View Alarm Zones Status»).
IMPORTANT!!
1 - If any of the installation detectors is detecting when the general system arming is being done, the system cannot
be armed until detection by the corresponding detector is finished.
In this case, the monitor emits an acoustic alert, beeping, that the alarm Zone is detecting. The number of beeps
emitted by the monitor indicates the zone that is detecting. (Example: 3 beeps = Zone 3).
2- Arming or disarming does not affect the alarm zones configured in «24-Hour Mode».
The zones configured as«24 Hours» set off the alarm every time their sensors are activated. (regardless of
arming/disarming).
Alarm zones configured as 24 hours are usually those dedicated to smoke detection , gas leaks and flooding, etc,
i. e. those alarms that you want to generate alerts even when the user is at home.
Notes: When arming/disarming, only those zones that have been configured as "Enabled" will be armed. The Kit
comes ex-works with all the alarm Zones configured Enabled, so that it is only necessary to arm or disarm the
system (entering the corresponding code) to activate alarms detection.
It is also possible to Enable/Disable Zones individually.
KEY SEQUENCE
Master Code + AA
Master Code + BB
EXAMPLE
1234AA
1234BB
Pag 23