Preliminary checks
•
Check that the gate structure is sufficiently sturdy and there are no points of friction.
•
Check the condition of the gate hinges and make sure they are adequately lubricated.
•
Make sure there is a mechanical stop in closing to prevent the gate going beyond its travel;
Fixing the brackets to the post and gate (Figures 1 and 2)
After having verified the optimum conditions for installation, fix the Base Plate to the post using
14 ∅ plugs and M8 screws, observing the minimum distance of 100 mm from the ground. Lock
the fastening plate to the gate with M6 screws, observing the values indicated and those
specified in table 1
.
Istruzioni, instructions Instrucciones
OPENING
A
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
90°
155 ÷ 210
105°
190 ÷ 210
105°
200
Figure 1
B
C
0
430
50
430
75
430
100
430
125
430
150
400
175
400
200
400
0
430
30
430
Table 1
D
230 max
230 max
230 max
230 max
230 max
230 max
230 max
230 max
230 max
230 max
14