Accessmatic accesloop500 Manual De Usuario página 17

Sensores de cuerpos metálicos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

accesloop
500 5242
Opening your life
Operating status indicator
The vehicle detector will start self-calibration after turning on the power supply. In the course of self-calibration, "POWER"light keeps
normally ON, "DETECT"light indicates working sensitivity degree with ashing times。 "H"gear ashes 3 times, "M"gear ashes 2times,
"L"gear ashes 1 time。 After self-calibration , "DETECT"light is auto-o , the system is at waiting state。 When there is vehicle traveling on
the coils , "DETECT"light will light on while "DETECT"light will ash on if the coil is not detected in the calibration process.
Sensitivity adjustment and reset
Detection sensitivity has three degrees:(High、 Middle 、 low) and can be set by the toggle switch as showed in Figure 2。
Figure 2.
"H": HIGH
"M": MEDIUM
"L": LOW
Fig. 2
Fig. 3
Front panel
Reset Function
The reset function can be realized by inter-conversion between any two gears as Figure 3
Function Set
1. Operating Mode Conversion
Vehicle detector includes presence output and pulse output, the internal dip switch can achieve the conversion 。
SW1 is "ON" ,status signal output from Relay1, No output from Relay2 ;
SW1 is "OFF", (SW1 lie at the end with numbers) , status signal output from Relay1, pulse signal output from Relay2 ( pulse width: 200ms).
www.accessmatic.com
2
Tabla de contenido
loading

Este manual también es adecuado para:

Accesloop5242

Tabla de contenido