USAGE
y This device helps keep food warm with a bain-marie, and cannot be used to reheat or cook food.
y In compliance with the regulations in force, food in the bain-marie must be kept at a temperature higher to
63 °C.
TECHNICAL DESCRIPTION
L x W x H (mm)
Net weight
Maximum load
Power
Amperage
Voltage
Protection index
EU approved. The electric heating unit conform to NF EN 60335-1, NF EN 60335-2-50 standards.
Tank for one GN1/1 H200 mm max container or multiple base.
y Built-in opening dimensions :
- tank: 353 ± 1mm x 580 ± 1mm.
- control panel: 117 ± 1mm x 120 ± 1mm. Secure the panel using two 5mm diametre screws, not supplied.
- maximum control panel offset as regards the tank: 800 mm.
ELECTRICAL CONNECTION
y H05RNF cable with connecting plug supplied with the device, 1 mm² cross section, 2 phases + ground.
y 230 V voltage, 50/60 Hz single-phase.
y The device must be connected to a 10/16 Amp singe-phase socket with ground and will be connected to a
high sensitivity differential device and protected against overcurrent.
y Before plugging or unplugging the device, make sure the main switch on the left-hand side of the device is
off and in 0 position.
y The device cannot be connected without the single-phase plug. We shall not be held liable for any modifi-
cation.
DRAIN CONNECTION
y Install a drain pipe with a 3/4'' female coupling on the valve located under the tank.
OPERATION
y Make sure the outlet valve is shut and the main switch on "0».
y Fill the tank with hot water up to the mark on one of the tank's vertical panels:
- lower mark in order to use it with 200 mm high gastronorm containers.
- upper mark in order to use it with gastronorm containers under 200 mm.
y Put a lid on the tank for the water to heat up more quickly.
y Set the switch in "1».
y The thermostat enables water temperature to be adjusted. To keep food above 63°C, set thermostat to
100°C.
y Water must be preheated to at least 90 °C before putting the food in.
TANK DRAINAGE
y Open the valve. Caution: water temperature ranges from 90/100 °C.
CAUSES OF FAILURE
y Nothing starts up, when the device is switched on :
- check power supply.
y Tank water does not heat up :
- check thermostat setting.
- the safety thermostat has disconnected the device. Contact your dealer.
y For any other failure, contact your dealer.
ENGLISH
600 x 380 x 360
13 kg
30 kg
700 W
3 A
230 V single phase 50/60 Hz
21
- 5 -