Anleitung HR 100 Herkules
GB
Correctly using the device
¼
The high-pressure cleaner must be horizontally
placed on a flat, secure surface.
¼
It is recommended that you maintain the correct
operating position every time you use the machi-
ne by placing one hand on the pistol and the
other on the lance.
¼
Never direct the water jet toward electrical lines
or the machine itself.
¼
It is normal for the pump to leak a little; this is
necessary to avoid damage to the pump when it
is at a standstill.
Maintenance
Checking the water intake filter (Fig. 6)
Periodically check the intake filter in order to prevent
clogging, which could jeopardize operation of the
pump.
To do this, unscrew the connection coupling for the
water inlet hose from the device and clean the expo-
sed inlet sieve by placing it under running water.
Long periods of nonuse (electric pump)
If the machine is going to be stored for longer peri-
ods of time (i.e. over three months) in a room where
frost could develop, it is recommended that the
machine be filled with an antifreeze solution (similar
to the antifreeze solutions used for vehicles).
When the device is not used for an extended period
of time, lime deposits begin to form in the electric
pump, which in turn can lead to starting difficulties.
Electric motor
The electric motor is equipped with a motor circuit
breaker switch. When the motor starts to run hot, it is
cut out by this switch. Turn off the device with the
foot switch (1). Wait
5 - 10 minutes before using the device again. Try to
determine the cause of the fault. If the problem
repeats itself, please contact a customer service cen-
ter.
10
18.03.2004
15:24 Uhr
Technical data
Rated voltage:
230 V ~ 50 Hz
Power rating:
Working pressure:
System pressure (EW bar):
Output:
Suction height:
Max. water inlet pressure:
LPA sound pressure level:
LWA sound power level:
Weight:
Seite 10
1100 watts
60 bar
max. 100 bar
360 l/h
1 m
7 bar
86.2 dB (A)
102 dB (A)
11.9 kg