10. ELECTRICAL CONNECTIONS
1.
Unscrewing the fastening screws, remove the cover of the control unit. Connect the power supply output (DC
OUT) to the control unit respecting the polarity (Figure 12).
+ -
12Vdc
2.
Connect the control unit to the terminal of the vacuum/s.
The Aspirvelo Air Ecocomfort can work with two ventilation units up to a maximum of four. The system is designed to
operate in an alternating way. If for example two units are installed, the first device operates by introducing air from
the outside, while the second device operates by extracting air from the room. When after some time there is the
inversion of the direction of rotation of the fans, the first device extracts the air to the outside while the second device
brings the air into the room. The alternation of operation in torque, ensures that the sum of the air flow emitted is
equal to the sum of the air flow extracted.
EXAMPLE OF CONNECTION WITH 4 MOTORS:
The pair of motors A-B is in counter phase with the
C-D pair (Fig. 13a)
FIXING SCREWS
Figure 13a
Figure 12
EXAMPLE OF CONNECTION WITH 2 MOTORS:
Motors A and C are in counter phase (Figure 13b)
E N G L I S H
A S P I R V E L O
AIR ECOCOMFORT
Figure 13b
17