Operating Instructions - SKF THAP 030 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
4

OPERATING INSTRUCTIONS

1. Air connection
2. Oil inlet
3. Oil return
4. High pressure oil outlet (G 3/4")
5. Release valve
6. Air valve, start/stop of pump
7. Locking clamp
a) Connect the pump to the workpiece, directly or via a high pressure hose.
b) Close air valve (6) and connect the air line (1) the oil suction hose (2) and the
oil return hose (3).
c)
Drop the free end of the oil hoses into an oil container and make sure that the
oil suction hose is well secured in the oil.
d)
Make sure the release valve (5) is open and start the pump by opening the air
valve (6). Let the pump run until no air bubbles can be seen in the return hose (3).
e)
Now close the release valve (5) and the pump will start injecting oil.
SKF THAP 030/150
9
Tabla de contenido
loading

Este manual también es adecuado para:

Thap 150

Tabla de contenido