1. GENERAL INFORMATION
Please read carefully and follow the instructions detailed in this manual. Keep the manual for use and future
maintenance.
2. TABLE OF TECHNICAL DATA AND MARK
The CE mark certifies that the anemometer conforms to the essential health and safety requirements laid
down by European product directives. The CE mark can be identified by the relevant adhesive label applied to
the outside of the product, on which are shown some of the data shown in the following table:
Power supply:
Relay contact:
Operating temperature:
Packaging dimensions:
Container:
The sensor essentially consists of a sensitive surface which is able to detect the presence of water. In order to
prevent condensation from building up and to facilitate evaporation, this surface is heated using an integrated
heating element which is activated as necessary. The heating of the sensitive surface should therefore be
considered normal. The condition of the sensor is monitored through the activation of two LEDs:
Reference Led
R HEAT
RAIN
The output contact is activated depending on the information detected by the sensor, in accordance with one
of the modes selected by the user though the SW1 dip switch:
Monostable Time 1 sec
Led off
Heating off
No precipitation
Time 3 min
Time 12 hours
RS
230 Vac 50-60Hz 4,5W max.
N.A. 5 A 30 Vdc; 5 A 250 Vac
-10 / 70°C
240x185x110 mm.
PC+ABS UL 94V-0 ( IP54 )
Led on
Heating on
precipitation detected
2