Dimensions and Positioning of the Device

In accordance with the product standards, the charging station must be located at height "y" (I-1) between
1.30 m and 1. 6 0 m above ground level. We recommend mounting the charging station at a height of 1.40 m.
Remember that local regulations may limit this height. It is mandatory to consider the following precautions:
• The mounting area required for the Wallbox
charging station is at least 250x150 mm
(height by width) (I-1).
• When installing the Wallbox, the cable should
easily reach the vehicle inlet.
• For a safe operation of your charging station,
you must observe the minimum distances
recommended to other technical installations.
• The plug holder (I-2) should be placed
at a height of between 0.50m and 1.50 m
above ground level. Maintaining a free area of
400 x 400 mm around it to provide sufficient
space for the ergonomics is recommended.
Correct installation is absolutely essential and is outside the scope of the liability of Wallbox.
Installation video available at https://wallbox.com/

Drill

• Use the drilling template as a guide to mark the place for the four anchor screws on the wall. Take special
care to keep the template level. The use of a spirit level is highly recommended.
• Drill the anchor hole marks to the diameter specified for the selected equipment for the installation. For
installation on wood, brick and concrete walls use the equipment delivered with the charger.
Make sure the power supply is turned off during all mounting steps.

Mounting

1. Opening the device
Step 1.1: Remove the two screws on the bottom side
of the frame and remove it (I-3).
Step 1.2: Remove the six screws of the front cover.
Step 1.3. Carefully open the cover.
Step 1.4. Disconnect the ribbon cable from the cover.
I-1: Mounting area
150 mm
150 mm
*between 1.30 m and 1.60 m above ground level
1.
2.
400 mm
I-2: Maintaining
distance around plug
holder
I-3
9