Jandy
Pro Series VS FloPro
®
6.2
service Technician Maintenance
Warning
This pump must be serviced by a professional
service technician qualified in pool/spa installation.
The following procedures must be followed exactly.
Improper installation and/or operation can create
dangerous electrical hazards, which can cause high
voltages to run through the electrical system. This can
cause property damage, serious personal injury, and/or
death. Improper installation and/or operation will void
the warranty.
6.2.1
Blocked impeller
Warning
Before servicing the pump, switch off the circuit
breakers at the power source. severe personal
injury or death may occur if the pump starts while
your hand is inside the pump.
1.
Turn off the pump. Switch off the circuit breaker
to the pump motor.
2.
Remove the lid and basket.
3.
Look inside the pump for debris. Remove any
debris found inside.
4.
Replace the basket and lid.
5.
Switch on the circuit breaker to the pump motor.
6.
Turn on the pump, and see if the problem is
solved.
7.
If the impeller is still blocked with debris and it
is not possible to remove the debris using Steps 2
through 4, the pump will need to be disassembled
in order to access the inlet and outlet of the
impeller.
6.2.2
impeller removal and replacement
Warning
Before servicing the pump, switch off the circuit
breakers at the power source. severe personal
injury or death may occur if the pump starts while
your hand is inside the pump.
1.
Turn off the pump. Switch off the circuit breaker
to the pump motor. If you are not replacing the
motor, do not disconnect the electrical wiring.
noTE
If you are replacing the motor, Zodiac Pool Systems,
Inc. strongly recommends that a qualified service
technician or electrician properly disconnect the
electrical wiring at the pump motor.
|
Variable-Speed Pump
Installation & Operation Manual
™
2.
Turn off any valves to prevent pool water from
reaching the pump. Drain the water from the
pump by loosening the unions or removing the
drain plugs.
3.
Using a 9/16" wrench, loosen the bolts connecting the
pump body to the motor backplate. See Figure 13.
Fan Cover
Figure 13. remove the pump housing
4.
Pull the motor and backplate out of the pump
body. Remove the pump body o-ring. The
impeller is connected to the motor shaft.
5.
Using a No. 1 Phillips screwdriver, remove the
two (2) screws holding the diffuser. (The diffuser
is the cover over the impeller.) Then remove the
diffuser (See Figure 14).
6.
Access the inlet and outlet of the impeller and
remove any debris.
Backplate
Figure 14. remove the diffuser
Page 19
English
Pump Body
Motor Backplate
Bolts (6)
Diffuser
Screws (2)
O-ring