3. Screw the 4 lag screws provided firmly fixing the base of the dryer
to the wall.
4. Connect the electric pair to the terminal strip.
5. Fit the cover of the dryer.
- Introduce the cover from the front
- The base clips will fit into their respective accommodations on the
cover.
- Move the cover upwards.
- Introduce and fix the 2 lower screws with the help of the special key.
NOTE: Please plan for a minimum distance of 40 cm (15.80") in relation to
possible shelfs, marble surfacesor washing basins. Avoid as much as
possible the presence of reflecting surfaces in the area of actuation of the
appliance IR sensors.
Machine must be manipulated only by an autorized technician.
ATTENTION: Whilst removing the cover, electrical live parts of the
appliance are accesible.
Means for disconnection with contact separations at least 3 mm (0.12")
must be incorporated in the fixing wiring.
During the installation process, the protection areas should be considered
according to norm VDE 0100.
The hand dryer must only be installed on a closed surface (wall, partition or
similar.