Electric Connection - Pentair Jung Pumpen DRENA-LINE BIOX 200/8 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

WARNING
Make sure that float switch off pump, when at min. level of liquid.
WARNING
Make sure no obstacles stand in the way of oat switch, during up/down swinging.
DANGER
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
DANGER
Pollution of the liquid could occur due to the leakage of lubricants.
CHAPTER 4

ELECTRIC CONNECTION

WARNING
Ensure tension and frequency of pump (read motor plate) and supply network are
same.
DANGER - ELECTRIC SHOCK RISK
Installer must make sure that electric current network has ground wire conforming
to current laws.
DANGER - ELECTRIC SHOCK RISK
Make sure that electric current network is provided with a high-sensitivity
circuit-breaker ∆=30 mA (DIN VDE 0100T739).
SINGLE PHASE VERSION
Single phase pumps are equipped with double ground contact plug at top end of supply cord ; in this
case grounding is done when plugging in.
THREE PHASE VERSION
In this case the ground wire (yellow-green cable) of supply cord must be connected to ground wire of
electric current network. Ensure connection to electric current network by using an
omnipolar-sectionned magneto thermic circuit-breaker.
This will ensure effective disconnection from electric current network.
OVERLOAD PROTECTION
BIOX range pumps have a built-in thermal overload with automatic reset. Further protections are
not required. BIOX range three phase pumps can be protected by using a magneto-thermic motor
protector or a contactor with thermal relay; in both cases they have to be rated conforming to
nominal power showed on motor plate.
Eventual electric oat switch must be connected to auxiliary connector buckles.
ROTATION DIRECTION TESTING THREE PHASE PUMPS
Water head and delivery are terribly effected by wrong rotation of shaft of pump motor. Clock wise
rotation is correct (upside view of pump). When startin the pump motor will ungergo an anti-clock
wise back-kick. In this case test is positive; on contrary case, please disconnect pump from network
and inverse two phases.