CONNECTIONS DIAGRAM (SEE DIAGRAMS PICT.2)
A. Single phase manual pump
1. START (green)
2. RUN (red)
3. COMMON (black)
4. CAPACITOR
CHAPTER 5

MAINTENANCE AND TROUBLESHOOTING

DANGER - ELECTRIC SHOCK RISK
Before doing any operation, make sure pump is disconnected from electric current
network.
DANGER - ELECTRIC SHOCK RISK
Power cord must be replaced by manufacturer or by Customer service, using special
tools.
No maintenance is required when BIOX range pumps operate in normal conditions.
Occasionally maintenance of liquid ends and replacement of impeller may be required.
FAULT
PUMP DOES NOT
DELIVER, MOTOR DOES
NOT RUN
PUMP DOES NOT
DELIVER, MOTOR RUNS
PUMP DELIVERS
REDUCED WATER
INTERMITTENT
WORKING
8
B. Single phase automatic
pump
5. SUPPLY CORD
6. GROMMET
7. PLUG
8. YELLOW-GREEN
POSSIBLE CAUSE
1) No electric current supplying.
2) Incorrect plugging in.
3) Circuit-breaker come into operation.
4) Impeller blocked.
5) Motor or capacitor damaged.
1) Filter obstructed.
2) Non return valve blocked.
1) Filter partially obstructed .
2) Delivery pipe partially obstructed.
3) Impeller worn off.
4) Anticlockwise rotation (three phase
version).
1) Solids obstruct impeller.
2) Too warm liquid.
3) Motor broken.
C. Three phase pump
9. WHITE
10. LIGHT BLUE <LINE>
11. BROWN <LINE>
12. FLOAT SWITCH
REMEDY
-
Verify presence of electric current
supply and plug in.
Reinforce circuit-breaker. Please call
electrician in case circuit-breaker
comes again into operation.
Remove obstacle.
Call dealer.
Clean lter.
Clean or replace valve.
Clean lter.
Remove obstacles.
Replace impeller.
Inverse two phases.
Remove obstacles.
-
Call dealer.