Ce Conformity Declaration - Modellsport MULTIPLEX SafetySwitch 6 HV Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

!
Note
We recommend the use of the SAFETY-SWITCH 6HV in
models fitted with up to six standard or four digital / high-
performance servos. Above this number you should use
the SAFETY-SWITCH 12HV or SAFETY-SWITCH 12HV
TwinBatt.
!
Note
For safety reasons we also recommend the use of a Peak
Filter (# 8 5180) in conjunction with the SAFETY-SWITCH
TwinBatt, as voltage peaks which may be induced by high-
performance servos cannot be buffered from the receiver
batteries due to the blocking action of the battery backer
diodes.
3.
S
PECIFICATION
SAFETY-SWITCH
6HV
Order No:
# 8 5006
Cell count:
Permissible con-
max. 6 A
tinuous current:
Idle current
drain*:
Receiver lead:
1 x 0.33
2
mm
UNI ap-
prox. 200
prox. 200
mm long
mm long
Battery
MPX MP-
connectors:
RC plug
Dimensions
approx.
(L x W x H):
38 x 28 x 6
38 x 28 x 6
mm
Weight:
approx.
(incl. leads)
20 g
Special features
!
Note
* The stated idle current flows when the mechanical slide switch
is in the OFF position. For this reason you should always
disconnect the receiver battery from the SAFETY-SWITCH if the
model is to be stored for a long period. This will prevent any risk
of the receiver battery becoming deep-discharged.
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating instructions SAFETY- - - - SWITCH 6HV
Operating instructions SAFETY
Operating instructions SAFETY
Operating instructions SAFETY
SAFETY
SAFETY
SAFETY- - - - SWITCH 12HV / 12HV (M6) / 12HV TwinBatt / 12HV TwinBatt (M6)
SAFETY
SWITCH 12HV / 12HV (M6) / 12HV TwinBatt / 12HV TwinBatt (M6)
SWITCH 12HV / 12HV (M6) / 12HV TwinBatt / 12HV TwinBatt (M6)
SWITCH 12HV / 12HV (M6) / 12HV TwinBatt / 12HV TwinBatt (M6)
12HV
12HV (M6)
12HV
TwinBatt
# 8 5007
# 8 5008
# 8 5009
2S LiPo / LiXX or 4 – 6 NiXX cells
max. 12 A
approx. 2.5 mA (in OFF state)
2 x 0.33
1 x 2.5
2 x 0.33
2
2
2
mm
mm
mm
UNI ap-
M6 approx.
UNI approx.
200 mm
200 mm
long
long
MPX M6
MPX M6
2 x MPX M6
plug
plug
plug
approx.
approx.
approx.
38 x 28 x 6
50 x 40 x 10
mm
mm
mm
approx.
approx.
approx.
25 g
30 g
35 g
Battery
backer /
2 sensor
sockets [V]
SWITCH 6HV
SWITCH 6HV
SWITCH 6HV
4.
G
UARANTEE
The company MULTIPLEX Modellsport GmbH & Co.KG accepts
no liability of any kind for loss, damage or costs which are due to
the incorrect use and operation of this product, or which are
connected with such operation in any way. Unless the law
expressly states otherwise, the liability on the part of MULTIPLEX
Modellsport GmbH & Co.KG to pay damages, regardless of the
legal argument employed, is limited to the invoice value of those
products supplied by MULTIPLEX Modellsport GmbH & Co.KG
which were directly involved in the event in which the damage
occurred. This does not apply if liability is incurred according to
statutory law on account of intentional or gross negligence.
We guarantee our products in accordance with the currently valid
statutory regulations. If you wish to make a claim under
guarantee, your initial course of action should always be to con-
tact the dealer from whom you purchased the equipment.
12HV Twin-
The guarantee does not cover faults and malfunctions which are
Batt (M6)
caused by the following:
# 8 5010
Incorrect or incompetent use
Maintenance carried out incorrectly, belatedly or not at all,
or not carried out by an authorised Service Centre
Incorrect connections
The use of accessories other than genuine MULTIPLEX
1 x 2.5
items
2
mm
Modifications or repairs which were not carried out by
M6 approx.
200 mm
MULTIPLEX or by an authorised MULTIPLEX Service
long
Centre
2 x MPX M6
Accidental or intentional damage
plug
Defects due to normal wear and tear
approx.
50 x 40 x 10
Operation of the unit outside the limits stated in the
mm
specification
approx.
Operation of the unit in conjunction with equipment made by
35 g
other manufacturers.
Battery
backer /
5.
CE C
ONFORMITY
2 sensor
sockets [V]
This device has been assessed and approved in
accordance with European harmonised directives.
This means that you possess a product whose design and
construction fulfil the protective aims of the European Community
designed to ensure the safe operation of equipment.
The detailed CE conformity declaration can be downloaded in the
form of a PDF file from the Internet under www.multiplex-rc.de. It
is located in the DOWNLOADS area under PRODUKTINFOS.
6.
D
ISPOSAL
Electrical equipment marked with the cancelled waste bin
symbol must not be discarded in the standard household
waste; instead it should be taken to a suitable specialist
disposal system.
In the countries of the EU (European Union) electrical
equipment must not be discarded via the normal domestic refuse
system (WEEE - Waste of Electrical and Electronic Equipment,
Directive 2002/96/EG). You can take unwanted equipment to
your nearest local authority waste collection point or recycling
centre. There the equipment will be disposed of correctly and at
no cost to you.
By returning your unwanted equipment you can make an
important contribution to the protection of the environment!
/ L
E
IABILITY
XCLUSION
D
ECLARATION
N
OTES
Page 2/2
Tabla de contenido
loading

Este manual también es adecuado para:

Multiplex safetyswitch 12 hvMultiplex safetyswitch 12 hv m6Multiplex safetyswitch 12 hv twinbattMultiplex safetyswitch 12 hv twinbatt m6

Tabla de contenido