en
10 | CRR 220 | Scope of delivery / Accessories
2.
Scope of delivery /
Accessories
Scope of delivery
R
CRR 220
R
Accessory set (voltage stabilizer connection)
R
Operating instructions
Accessories (to be ordered separately)
Designation
Voltage stabilizer
Adapter CRI/CRIN (K)
Adapter CRI/CRIN (AK)
Adapter CRIN (Terminal)
Instructions for using the voltage stabilizer:
Replace the enclosed power line with an IEC
plug, if necessary, with a power line with a
country-specific mains plug (100 – 230 V/
13 A). Never use AC adapters, such as travel
adapters!
¶
Do not overload the mains supply circuit
and the mains socket, if in doubt, contact
an electrician.
Fig. 1:
CRI/CRIN Adapter (K) - 0 986 613 506
Fig. 2:
CRI/CRIN Adapter (AK) - 0 986 613 507
Fig. 3:
CRIN Adapter (terminals) - 0 986 613 508
|
0 986 629 503
2020-08-24
3.
Please take the packaging for recycling to the
appropriate collection points. In countries other
than Germany, please consult the appropriate local
regulations.
4.
!
The following safety instructions do not claim to
Order number
be exhaustive and only relate to work performed
1 687 022 873
directly on the components.
0 986 613 506
!
0 986 613 507
Observe the applicable accident prevention
0 986 613 508
regulations. It is assumed that personnel who work
on the system will be suitably qualified and that they
carry out the work conscientiously and in the proper
manner!
!
Make sure that systems and devices are only used
for their intended purpose.
!
Shut off the power before disconnecting /
connecting wires or connectors. Avoid sparks!
!
Only operate the CRR 220 with suitable voltage
stabilizer 24V DC/ ≥ 20 A.
!
The voltage stabilizer's earth wire (PE) must be
connected.
!
The 24 V (-) connection must be connected to the
protective earth conductor (PE); refer to Chapter 6
(Electrical Connection).
!
Please observe the correct polarity when connecting
the CRR 220; the device should never be used with
the polarity reversed.
!
Never operate the CRR 220 with worn or defective
accessories.
!
Degree of protection IP 20: Only use the device in
the prescribed testing room.
Environmental protection
Safety instructions
Robert Bosch GmbH