DEHUMIDIFICATION (DRY)

When the air conditioner is in the dehumidification mode, it doesn't cool the room.
When you use the air conditioner in the dehumidification mode, you don't have to
use the flexible tube. For maximum dehumidification efficiency leave the rear dis-
charge outlet free to discharge directly into the room.
G
Remove the flexible tube by grasping it at the attachment point on the air condi-
tioner and twisting it until you release it from the blocking hooks.
EG
Press the ON /OFF push button (A)
G
Select dehumidification mode pressing the push button (B)
lights up
. The humidity of the room (condensate water) will be collected in
the internal tank of the air conditioner.
G
To stop the air conditioner press again the ON/OFF push-button. (A).
WARNING !
The air conditioner may be used as dehumidifier only if the room temperature is
above 10 °C. When the room temperature is below 10 °C, the compressor stops
and the dehumidification doesn't occur, while the fan goes on working.
ATTENTION:
the control causes a compressor starting delay of about three minutes each
time buttons A, B and thermostat D are activated or when the plug of supply
electric cable is took out and in.
SETTING AIR FLOW DIRECTION
To set the air flow direction, seize with both hands one of the deflector blades and
pull towards you
HOW TO DISCHARGE THE WATER TANK
The air conditioner removes humidity of the air, collecting the condensate into
the internal tank. The condensate water can be evacuated through the external
discharge tube located on the rear of the unit.
G
When the internal tank is full, the air conditioner will automatically stop and the
water tank alarm (yellow)
The tank capacity allows approx. 6 hours operation.
G
Verify the presence of water inside the air conditioner, looking at the rear exter-
nal discharge tube.
G
Press the ON /OFF push button to switch off the unit, then unplug the cable.
G
Position a container under the discharge tube.
G
Grasp the tube removing it from its seat on the rear of the air conditioner
G
Close with the inch the open end of the tube and, tilting it towards the container,
let the condensate water flow.
G
At the end of the operations reinsert the discharge tube into its place.
WARNING
G
Always switch off the air conditioner before unplugging it from the power socket.
G
Always unplug the air conditioner before discharging the condensate water col-
lected inside.
4
to start the air conditioner.
begins flashing.
, lamp (H)
B
Vertical Flow
H
A
C
D
Horizontal Flow