Mounting the converter
5.1
Control elements
No. in
fig. 1,
Explanation
page 3
1
Output terminals
2
"Power On" LED: There is voltage at the output terminals on the con-
verter. The converter is ready for use.
3
"Battery Low" LED: The input battery is no longer sufficiently
charged.
4
"Overload" LED:
– If a consumer is connected: The converter is shorted or over-
loaded.
– If connected as a charger: The converter is in the full current
charging phase.
5
Air outlet
6
Main switch
7
Red: Positive cable to input battery
Black: Negative cable to input battery
8
Connection for switching on with on-board voltage (e.g. ignition or
external switch)
6
Mounting the converter
6.1
Mounting instructions
If you wish to mount the converter in a fixed position, please observe the fol-
lowing mounting instructions:
You can mount the device either horizontally or vertically.
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system
must be present for installations in small, closed spaces. The minimum
clearance around the device must be at least 5 cm (fig. 2, page 3).
30
PerfectCharge/PerfectPower
EN