The iControl mobile is an electronically controlled
solenoid block, which has a mixed water connec-
tion and must be connected with 3 consumers.
These consumers can be activated simultaneously,
individually, in twos or threes.
Standards and guidelines:
The use of the product is warranted by the following guidelines::
EN 15200
EN 60335-2-105
Safety Notes:
The shower system may only be used for bathing, hygienic and
body cleansing purposes.
Children must not use the shower system without supervision.
Children as well as adults with physical, mental and/or senso-
ric impairments must not use this shower system without proper
supervision. Persons under the influence of alcohol or drugs are
prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be kept
between the shower and you.
The hot and cold supplies must be of equal pressures.
The product is not designed to be used with steam baths!
Electrical connection:
The installation and testing work must be performed by a skilled
electrician in observance of VDE 0100 part 701 and IEC 60364-
7-701.
Only one socket is required for the electrical connection. The
power is supplied via an external transformer.
No easily inflammable material is allowed in the immediate
vicinity.
The ambient temperature must not be higher than 50ºC.
The entire power is supplied via a 230V/N/PE/50Hz AC con-
nection.
The system must be protected via a leakage current protective
device (RCD/ FI) with a measurement difference current of ≤
30 mA.
If a potential equalisation is required, this must be done on site.
The current version of the applicable regulations from VDE, local
authorities and utility companies must be observed for electric
installation work.
It must be ensured that the product can be disconnected from the
mains. Either via a freely accessible plug or via an all-pin switch
as per EN 60335-1, sect. 24.3
10
English

Technical Information

The iControl mobile must be installed together
with the highflow thermostat (in the wall; part no.
15715000 + 01800180) and connected with the
included empty conduit.
This special empty conduit connects the
solenoid block to the receiver!
Outlet 1
hot
Assembly see page 133 + 135
Starting on page 133, different installation designs
with connection examples are shown to ensure a
flawless installation and function.

Installation Instructions:

Important! The fitting must be installed, flushed and
tested after the valid norms. (Installation to EN 1717)
See installation instructions::
Raindance Rainfall 28411000
Raindance Rainmaker 28403000 / 28404000 / 28417000
/ 28418000
Any work may only be carried out in a de-energized state.
The basic body 15941180 can only be installed vertically!
Installation with adjustment ring (A) only possible in the front
and middle sections!
All components must remain accessible.
Concealed installation:
"iBox iControl mobile" must be installed above "iBox High
Flow".
The mixed water flows from the output "iBox High Flow" and
flows into the input "iBox IControl mobile".
Outlet 2
Input
Outlet
Depth of fitting: _1e mm to _1f mm.
The iBox can depending on the building application be mounted
in different ways, Installation examples please see page 121.
iControl mobile
Outlet 3
High Flow
cold