Technical Data; Care And Maintenance; Electrical Circuit Diagram - Trotec TTK 50 S Instrucciones De Uso

Tabla de contenido
4. Remove heavy soiling by washing in warm soapy
water, max. 40 °C. Then rinse in fresh water
(diagram H).
5. To avoid damage to the apparatus, please note that
the air intake filter must be undamaged and completely
dry before being reinserted.
The apparatus must never be operated without
an air intake filter installed!
Transportation of the apparatus
The apparatus is equipped with castors and a handle to
facilitate easy transportation.
• Before moving the apparatus, switch it off and remove
the mains plug from the socket.
• Then empty the condensate container. Please watch
out for subsequent dripping condensate.
• Do not pull the apparatus by its mains cable.

Care and maintenance

Regular preventative maintenance and observation of certain
prerequisites will guarantee fault-free operation and a long
service life.
After every period of prolonged operation, and at least once
per year, the apparatus should be checked and thoroughly
cleaned.
All moving parts have been treated with low-maintenance
permanent lubrication. The entire refrigeration system is
a maintenance-free hermetically-sealed system and may
only be maintained by authorised specialist companies.
The mains plug must be removed from the mains
socket before any work is carried out on the apparatus!
• Keep the apparatus free from dust or any other deposits.
• Only use a dry or damp cloth to clean the apparatus.
Do not use running water.
• Do not use cleaning agents that are caustic or contain
solvents and only use appropriate cleaning agents even
in the case of heavy soiling.
• Check the air intake filter regularly for fouling. It should
be cleaned or replaced as necessary.
Work on the refrigeration system and the electrical
equipment may only be carried out by an authorised
& qualified company!
Cleaning the condenser and evaporator
This work requires the apparatus housing to be opened,
and therefore may only be carried out by authorised
& qualified companies!
• Clean the condenser and the evaporator either by blowing
or sucking them through, or by using a soft brush. Do not
use running water.
• Please note that the fins can easily be damaged or bent.
• Carefully clean the inside surfaces of the apparatus, the
condensate pan with hose connection, the ventilator and
the ventilator housing.
• Reinstall all dismounted parts correctly
• Check that the apparatus is functioning correctly
and carry out an electrical safety examination.
Important recycling information!
The apparatus uses the environmentally-friendly and ozone-
neutral refrigerant R134a. In accordance with legal stipulations,
or those that apply locally, the refrigerant/oil mixture used in
the apparatus must be disposed of correctly.
In the European Union electronic equipment
must not be treated as domestic waste, but
must be disposed of professionally in
accordance with Directive 2002/96EU of the
European Parliament and Council of 27th
January 2003 concerning old electrical and electronic
equipment. At the end of its life please dispose of this
instrument in a manner appropriate to the relevant legal
requirements.
B - 3
Troubleshooting
The fault-free operation of the apparatus has been confirmed
by repeated tests at the factory. However, if a loss of function
should occur, please check the apparatus in accordance with
the following list.
The apparatus will not start:
• Check the mains connection. 230 V / 1~ / 50 Hz.
• Check the inbuilt mains fuse. 10 A.
• Check the mains plug for damage.
The apparatus runs, but no
condensation formation:
• Check that the condensate container is positioned
correctly and is not full. The tank warning lamp should
not be lit (diagram C.6).
• Check that the condensate container microswitch
is functioning correctly.
• Check the room temperature. The working range
of the apparatus is between 5 and 35 °C.
• Check the air humidity: minimum 40 % relative humidity.
• Check the selected operating mode. The air humidity in
the place of operation must be above the selected level.
If necessary, turn the rotary control switch clockwise in
the direction of "Permanent operation" (diagram D.5).
• Check the air intake filter for fouling. Clean or replace
it if necessary.
• Have the heat exchanger fins checked for soiling.
This examination requires the apparatus to be opened
up and hence must be carried out by an authorised
specialist company.
The mains plug must be removed from the
mains socket before any work is carried out on
the apparatus.
The apparatus is making a lot of noise or
vibrates, condensate is running out:
• Check that the apparatus is standing upright on
a level surface.
• Have the condensate pan and connection piece checked
for fouling. This examination requires the apparatus to
be opened up and hence must be carried out by an
author ised specialist company.

Electrical circuit diagram

Operating manual dehumidifier TTK 50 S
If the apparatus does not function correctly after carrying
out the above checks, please contact an authorised
specialist company.
Work on the refrigeration system and the
electrical equipment may only be carried out by
a specially authorised & qualified company!

Technical data

Working range temperature
Working range humidity
40-100 % relative humidity.
Dehumidification performance max.
at 30 °C / 80 % relative humidity
Air performance max.
Refrigerant
Refrigerant quantity
Electrical connection
Frequency
Nominal current max.
Power consumption max.
Inbuilt fuse
Sound pressure level LpA 1m
1)
Condensate container
Depth
Width
Height
Weight
1) Noise measurement DIN 45635 - 01 - KL 3
5 - 35 °C
18l / day
14l / day
120 m
3
/h
R 134a
1
0 4
g
230 V
50 Hz
1,2 A
240 W
10 A
41 dB (A)
3,5
l
220 mm
310 mm
530
m
m
2 1
g k
Tabla de contenido
loading

Tabla de contenido