5
MAINTENANCE AND TROUBLE SHOOTING
5.1
Maintenance
Regularly:
- Check and refill the upper oil reservoir with new, clean oil.
- Clean the oil leveller. For this purpose the lower reservoir is equipped with a
drainage neck with a magnetic plug.
5.2
Trouble shooting
In case of different oil levels in the application and the oil leveller check that:
- The application is provided with a ventilation nipple preventing over/under
pressure.
- The ventilation tube of the oil leveller is not clogged.
In the case the oil continues to flow from the upper reservoir despite the pre-set
level having been reached:
- Ensure the cover and the oil inlet on the upper reservoir is properly sealed.
In the case of excessive oil consumption check the application for leakage.
5.3
Spare parts
Designation
LAHD 500-1
LAHD 1000-1
LAHD-1
LAHD-2
SKF LAHD 500-1000
Description
Upper reservoir with gaskets, 500 ml
Upper reservoir with gaskets, 1000 ml
Lower container with ventilation tube and gaskets
Lubrication tube with end fittings (1 m)