CoolFreeze
In HIGH mode, the battery monitor responds faster than at the levels "LOW" and
"MED" (see the following table).
Battery monitor mode
Cut-off voltage at 12 V
Cut-in voltage at 12 V
Cut-off voltage at 24 V
Cut-in voltage at 24 V
This is how to select the battery monitor mode (fig. 1, page 3 and fig. 2, page 3):
➤ Switch on the cooler.
➤ Press the "SET" button (4) three times.
➤ Use the "+" (6) and "–" (7) buttons to select the battery monitor mode.
✓ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode HIGH. When the cooler is connected to a supply battery,
the battery monitor mode LOW will suffice.
If you wish to operate the cooling device from the AC mains, set the
battery monitor to LOW.
6.10

Switching off the cooling device

fig. 1, page 3, fig. 2, page 3
➤ Empty the cooling device.
➤ Switch the cooling device off: Press the ON/OFF button (1) for three seconds.
➤ Disconnect the plug.
If you do not want to use the cooling device for a longer period of time:
➤ Leave the lid slightly open. This prevents odours from building up.
EN
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
Operation
HIGH
11.8 V
12.6 V
24.6 V
26.2 V