Monitoring The Brush Resistance - Kerbl 18870 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63

4.3.1. Monitoring the brush resistance

The device monitors the current used by the motor and therefore checks the correct functioning of the cow brush.
If the gear motor is placed under too much strain, the brushes stand still and then move in the opposite direction.
This can occur if the animals lean to far too one side or if a tail gets wound up in the mechanism.
If this occurrence is repeated more than five times, with the period between events being less than 6 seconds, the
control card triggers an alarm, the display shows fault "5" and the machine switches to its alarm state for 4 minutes. (=
motor disconnected / blown / power cable for motor defective alarm)
Caution: the setting must always be made according to the type of herd being cleaned. If the
setting is too high, the cattle may sustain injuries. The responsibility for this setting lies with the
customer.
The adjustment of the values should only be carried out when the machine is disconnected from
the power supply.
The threshold setting is lowest at setting ( - ) and highest at (+ ). If the setting is too high or too low for your animals,
here is where you can adjust it.
4.3.2. Setting the cycle time
The cycle time is set at the factory to 90 seconds. This value cannot be adjusted.
4.3.3. Explanation of display symbols and LEDs
Description of display messages:
Display
Model
No display
Dot
r
L
1
after 2015
1
up to 2015
2
after 2015
2
up to 2015
3
after 2015
3
up to 2015
4
5
Figure 6: Changing the fuse on CowCleaner Swing
10 A mains fuse
To change the fuse, press the fuse holder and turn in the direction of the arrow.
Remove fuse holder and insert a new fuse.
Description
No mains voltage
Flashing, machine ready
Motor running in normal rotational direction (right)
Motor running in inverted rotational direction (left)
Betriebsartschalter SW1 kontrollieren
Overvoltage alarm – over 270 V or over 140 V (#18XXX)
Platine beschädigt
Undervoltage alarm – under 180 V or under 85 V (#18XXX)
Betriebsartschalter SW1 kontrollieren
Control card overheating alarm (> 75°C)
Motor disconnected / blown / power cable for motor defective alarm
Motor blocked alarm
38
Tabla de contenido
loading

Este manual también es adecuado para:

Swing18770

Tabla de contenido