Trouble-Shooting; Corrective Action - SATA minijet 1000 K Instrucciones De Servicio

Ocultar thumbs Ver también para minijet 1000 K:
Tabla de contenido
Operating instructions SATAminijet 1000 K/H RP/HVLP
EN

10. Trouble-shooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
suction cup
Air bubbles appearing
in the suction cup
Spray pattern is too
small, crooked, lop-
sided or splitting
No function of round/
flat spray control - con-
trol knob can still be
turned
120
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the suction cup
Defective paint needle
seal
Clogged air cap drill-
ings
Damaged fluid tip (fluid
tip aperture)
Air distribution ring has
not been positioned in
correct location (pin is
not located in the drill-
ing) or damaged

Corrective Action

Tighten fluid tip [2-1]
with universal spanner
[7-4]
Replace air distribution
ring which will be dam-
aged during extraction
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean the nozzle set,
chapter 8, or replace,
chapter 9.1
Refill suction cup
Replace the paint nee-
dle seal, chapter 9.3
Clean air cap, observe
chapter 8
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
Replace the air dis-
tribution ring making
sure it has been posi-
tioned correctly when
inserting it, chapter 9.2
Tabla de contenido
loading

Este manual también es adecuado para:

Minijet 1000 h

Tabla de contenido