8.2

To change jaws

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (No. 2).
Unscrew jaw housing (No. 4).
Remove jaws (No. 5).
Clean jaw housing (No. 4) and grease sliding surfaces.
Fit new jaws (No. 5) from the front (they are held by the grease).
Reassembleinreverseorder,ensuringthatallpartsarefixedtight.
8.3

To top up hydraulic oil

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (No. 2).
Unscrew oil screw plug (No. 12) and seal (No. 13) using T20 Torx screwdriver.
Screwonsuppliedoilrefillreservoirwithcover.
Connect blind rivet setting tool to compressed air supply and press trigger (No. 40); then
disconnect blind rivet setting tool from compressed air supply.
Pourusedoiloutofoilrefillreservoir.
Filloilrefillreservoiruptothemarkwithhydraulicoil.
Carefullymovethepullpistonunitbackandforthbyhanduntilbubble-freeoilflowsout;
push back the pull piston unit as far as it will go and leave in this position.
Unscrewoilrefillreservoirandscrewinoilscrewplug(No.12)withseal(No.13).
Connect the blind rivet setting tool to the compressed air supply.
Carefully undo oil screw plug (No. 12) by 2 turns; the pull piston unit moves slowly into
the front end position. Collect leaking oil in a rag.
Tighten oil screw plug (No. 12).
Screw on steel head sleeve (No. 2).
Regular maintenance will extend the service life of your high-quality GESIPA
and they should be serviced at least every 2 years by an authorised workshop or by
GESIPA
Service. We recommend servicing tools that are subject to intensive use
®
ahead of schedule.