MAKE SURE THAT AIR FLOW IS DIRECTED
CORRECTLY
During summer operation, the cold air flow from the appliance
should never be directed towards the occupants of the room.
Also during heating operation, direct currents of air (even though
the relative temperature is higher than room temperature) can
cause a sensation of cold with consequent discomfort.
The louvers can be moved using the SWING button on the
remote control only in the versions equipped with the GLL M
grid. For other versions the louvers are moved manually.
An opening of 20° is recommended in heating mode and 10°
in cooling mode. These positions are indicated with two rai-
Position of the fins in heating operation, opening 20°.
Position of the fins in cooling operation, opening 10°.
INDICATIONS AND CONTROL BUTTONS
AUXILIARY COMMANDS ON THE UNIT
A - YELLOW TIMER LED
Switches on when the timer is activated.
B - "AUX" BUTTON (AUXILIARY COMMANDS)
Used when the remote control is out of order.
It allows the switching on in AUTO mode only, and the
switching off of the conditioner.
In AUTO mode the microprocessor, when starting up, based
upon the room temperature, selects the type of function and
stabilises the room temperature to be maintained as well as the
fan speed.
C - RED OPERATION LED
This comes on when the unit is working in heating mode.
C - BLUE OPERATION LED
This comes on when the unit is working in cooling mode.
D - RECEIVER
Receives the signals from the remote control.
VISUALISATIONS
Indicator lights • LEDs
A
C
C
Yellow
Red
Blue
● = On
❍ = Off
When the fins are closed ventilation is permitted.
Operation mode
Off
Stand by (unit off, timer active with automatic starting facility set)
Unit on, in cooling or dehumidification mode
Unit on, in heating mode
Unit on, in cooling or dehumidification mode (timer active awaiting automatic power down)
Unit on, in heating mode (timer active awaiting automatic power down)
sed lines on the louvers (see figure).
Ventilation is allowed with the louvers closed.
Pressing the SWING button, the four deflector louvres will turn
around their own axis alternately from the 0° position (louvre
closed) to the 20° position (louvre open in heating position).
On reaching the desired position, press the SWING button again
to block the louvres. On the contrary these will continue to turn
for a maximum time of 2 minutes and will then stop. In this
case, to modify the position, act on the SWING button again.
WARNING: Do not try to act manually on the deflector louvres
of the GLL M grid unit so as not to jeopardise functioning.