INSTALLATION / HANDLING
ELECTRICAL DATA
ALL UNITS IRN 7.5HP / 5.5kW
Standard voltage
Drive motor
Motor enclosure
Power
Full load current (maximum)
Starts per hour (maximum)
ELECTRICAL DATA
Control voltage
Maximum fuse rating
See note 1, 3
Minimum wire size AWG
2
(mm
)
See note 2, 3
Minimum wire size
dryer
2
AWG (mm
)
See Note 3
Maximum fuse rating
dryer
See Note 3
ELECTRICAL DATA
ALL UNITS IRN 10HP / 7.5kW
Standard voltage
Drive motor
Motor enclosure
Power
Full load current (maximum)
Starts per hour (maximum)
ELECTRICAL DATA
Control voltage
Maximum fuse rating
See note 1, 3
Minimum wire size AWG
2
(mm
)
See note 2, 3
Minimum wire size
dryer
2
AWG (mm
)
See Note 3
Maximum fuse rating
dryer
See Note 3
IRN 7.5 - 15 HP (5.5 - 11 kW)
Low Voltage
200V
230V
23.4
21.1
45A
45
8 (10.0)
10 (6.0)
Low Voltage
200V
230V
28.8A
26A
60A
60A
6 (16.0)
8 (10.0)
High Voltage
380V
400V
IP65
7.5HP / 5.5kW
12.0
11.4
20
24VDC
25A
25A
14 (3)
14 (3)
18 (0.9)
6A
High Voltage
380V
400V
IP65
10HP / 7.5kW
15.5A
14.7A
20
24VDC
30A
30A
10 (6.0)
12 (4.0)
18 (0.9)
6A
460V
11.7
25A
14 (3)
460V
14.5A
30A
14 (3)