G
B
- No changes may be made to the settings of the motor
or generator.
- Repairs and adjustment work may only be carried out
by authorized trained personnel.
sparks. Do not smoke!
- Do not touch any mechanically driven or hot parts. Do
not remove the safety guards.
above sea level 1000 m, relative humidity: 90 % (non-
condensing)
- The generator is driven by a combustion engine, which
therefore keep clear of these surfaces because of risk of
skin burns.
- The values quoted in the technical data for sound power
level (LWA) and sound pressure level (LWM) are emission
values and not necessarily reliable workplace values. As
there is a correlation between emission and immission
levels, the values are not a reliable basis for deciding on
any additional precautions which may be needed. Factors
properties of the work area, other sound sources etc.,
the number of machines and other processes in the
vicinity, as well as the time span in which the operator
is subjected to the noise. Also, the permitted immission
level can vary from country to country. Nevertheless,
with this information the user is able to make a better
assessment of the dangers and risks involved.
- Never use faulty or damaged electrical equipment (this
Any errors made in following the safety regulations and
serious injury.
2
2
and 100 m for 2.5 mm
.
Keep all safety regulations and instructions in a safe
place for future use.
3. Proper use
3. Proper use
The device is designed for applications operated with a
230 V alternating current source for SG 2200, SG 3000,
E-SG 2200, E-SG 4000 and with a 230 V and 400 V
alternating current source for SG 4200 and SG 5500.
Be sure to observe the restrictions in the safety
instructions. The generator is intended to provide electric
tools and light sources with electricity. When using the
device with household appliances, please check their
suitability in accordance with the relevant manufacturer's
instructions. In case of doubt, ask an authorized dealer
of the respective appliance. The machine is to be used
only for its prescribed purpose. Any other use is deemed
to be a case of misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries of
any kind caused as a result of this.
4. Technical data
4. Technical data
E -SG 2200
Generator type:
Protection type:
Continuous rated power Prated (S1):
Rated voltage Urated:
Rated current Irated:
Frequency Frated:
Drive engine design:
Single-cylinder forced air-cooled 4-stroke OHV
Displacement:
Fuel type:
Tank capacity:
Consumption at 2/3 load:
Weight:
Guaranteed sound power level LWA:
Power factor cos :
Power class:
Spark plug:
10
Synchronous
IP 23M
2.0 kW
2* 230 V~
8.7 A
50 Hz
3
196 cm
Normal unleaded petrol
3.5 l
o
/<0
C: 5W30)
528g/h
34.5 kg
95 dB(A)
1
G1
LG F6TC