Technical Specifications - Lincoln Electric POWERTEC Serie Manual De Instrucciones

Ocultar thumbs Ver también para POWERTEC Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22

Technical Specifications

POWERTEC 200C, 250C & 300C
Input Voltage
230 / 400V ± 10%
Three Phase
Duty Cycle
(
Based on a 10 min. period
200C:
35%
60%
100%
250C:
35%
60%
100%
300C:
35%
60%
100%
Welding Current Range
200C:
250C:
300C:
Fuse or Circuit Breaker Size
200C:
25A (for 230V) Superlag
16A (for 400V) Superlag
250C:
32A (for 230V) Superlag
16A (for 400V) Superlag
300C:
40A (for 230V) Superlag
25A (for 400V) Superlag
Height
815 mm
Operating Temperature
-10°C to +40°C
For any maintenance or repair operations it is recommended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
Input Power at Rated Output
200C:
7.5 kVA @ 35% Duty Cycle
250C:
10.8 kVA @ 35% Duty Cycle
300C:
14.4 kVA @ 35% Duty Cycle
RATED OUTPUT AT 40°C
Output Current
)
OUTPUT RANGE
25A - 200A
25A - 250A
30A - 300A
RECOMMENDED INPUT CABLE AND FUSE SIZES
PHYSICAL DIMENSIONS
Width
460 mm
INPUT
200A
150A
115A
250A
190A
145A
300A
225A
175A
Maximum Open Circuit Voltage
200C:
250C:
300C:
Input Power Cable
200C:
250C:
300C:
Length
925 mm
Storage Temperature
9
Frequency
50 Hertz (Hz)
Output Voltage
24.0 Vdc
21.5 Vdc
19.7 Vdc
26.5 Vdc
23.5 Vdc
21.2 Vdc
29.0 Vdc
25.2 Vdc
22.7 Vdc
37 Vdc
41 Vdc
43 Vdc
2
4 Conductor, 2.5mm
2
4 Conductor, 4mm
2
4 Conductor, 4mm
Weight
200C:
84 Kg
250C:
94 Kg
300C:
96 Kg
-25°C to +55°C
Tabla de contenido
loading

Este manual también es adecuado para:

Powertec 200cPowertec 250cPowertec 300c

Tabla de contenido