Technical description
6.2

Connections and controls

No. in
fig. 1,
Designation
page 3
1
POS (+)
2
NEG (–)
3
5A CHARGER/
2.5A charger
4
INV. AC OUTPUT 230 V inverter output
5
AC OUTPUT
6
AC INPUT
7
8
CIRCUIT
BREAKER
9
CHASSIS
GROUND
10
68
Explanation/function
Positive terminal
Negative terminal
5 A/2.5 A charger connection
 L: Live conductor
 N: Neutral conductor
 FG: Earth connection
230 V output
 L: Live conductor
 N: Neutral conductor
 FG: Earth connection
230 V input
 L: Live conductor
 N: Neutral conductor
 FG: Earth connection
Cover
LS: Circuit breaker (fig. 7, page 5)
The circuit breaker is triggered when there is
excess current or a short circuit.
➤ Eliminate the cause of the fault.
➤ Press the switch to reset the device.
Earth connection
Main switch:
 0: Off
 I: On
The main switch overrides the remote control set-
tings. When the main switch is in the "0" position,
you cannot switch on the device with the remote
control.