RH418NTE, RH418NTEG
• The cooling device must be levelled carefully to ensure proper function.
• For the glass door version: When the ambient humidity is above 65 % at 25 °C
ambient temperature, moisture will condense on the door.
• The socket outlet for the mains connection must be freely accessible.
5.1
Changing the decorative plate
➤ Change the decorative plate as shown (fig. 3, page 4 to fig. 6, page 4).
5.2
Reversing the door
➤ Reverse the door as shown (fig. 7, page 5 to fig. 0, page 5).
I
NOTE
The LED of the automatic door control (optional) must always be located
opposite the door hinge.
For versions with automatic door control, proceed as follows:
➤ Pull out the LED (fig. 1 3, page 3).
➤ Lay the cable in the guide.
➤ Insert the LED on the device's foot on the other side.
5.3
Fixing the cooling device
Ventilation (fig. a, page 6)
• Ventilation must be provided as shown in alternatives A, B, C or D.
• Ventilation grills (1), if used, must have openings of at least 200 cm² each.
• The minimum clearance between the cooling device's back and the surrounding
structure should be as follows:
No. in
fig. a, page 6
2
3
• The ventilation duct must at least measure 105 mm x the width of the cooling
device.
• The entire cooling unit must project into the ventilation duct as shown.
EN
Min. distance
20 mm
105 mm
Installation
15