Faber INCA LUX GLASS EV8 X/BK A70 Manual De Instrucciones página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
This cannot be washed or regenerated, and must be changed when led S1 starts to flash, or at
least once every 4 months. The Alarm signal, if it has been activated, only appears when the
Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation:
CHANGING
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press T3 and hold for at least 3 seconds, until LED flashes
three times in confirmation.
Changing the Filter
• Open the doors.
• Remove the Metal Grease Filter.
• Remove the saturated Activated Charcoal Filters, as indicated
(A).
• Fit the new Filters, as indicated (B).
• Replace the Metal grease filters.
• Close the doors.
• For replacement contact technical support ("To purchase
contact technical support").
EN
Activated Charcoal Filter (Recirculation Version)
Lighting unit
A
B
1
13
3
Tabla de contenido
loading

Este manual también es adecuado para:

Inca lux glass ev8 x/bk a52Inca lux glass ev8 x/wh a70Inca lux glass ev8 x/wh a52

Tabla de contenido