5. Transport, packaging and storage

5. Transport, packaging and storage

5.1 Transport

Check the temperature dry-well calibrator for any damage
that may have been caused by transport.
Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage
to property can occur.
When unloading packed goods upon delivery
as well as during internal transport, proceed
carefully and observe the symbols on the
packaging.
With internal transport, observe the
instructions in chapter 5.2 "Packaging and
storage".
If the instrument is transported from a cold into a warm
environment, the formation of condensation may result
in instrument malfunction. Before putting it back into
operation, wait for the instrument temperature and the room
temperature to equalise.

6. Commissioning, operation

Personnel: Skilled personnel
Protective equipment: Protective gloves
Only use original parts (see chapter 13 "Accessories").
WARNING!
Physical injuries and damage to property
and the environment caused by hazardous
media
Upon contact with hazardous media (e.g. with
flammable or toxic substances) and also harmful
media (e.g. corrosive, toxic, carcinogenic,
radioactive), there is a danger of physical injuries
and damage to property and the environment.
Should a failure occur, aggressive media and/
or with high temperature may be present at the
instrument.
For these media, in addition to all standard
regulations, the appropriate existing codes or
regulations must also be followed.
Wear the requisite protective equipment (see
chapter 3.5 "Personal protective equipment").
WIKA operating instructions, model CTD4000

5.2 Packaging and storage

Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection
during transport (e.g. change in installation site, sending for
repair).
Permissible conditions at the place of storage:
Storage temperature: -10 ... +60 °C [14 ... 140 °F]
Humidity: 30 ... 95 % relative humidity (non-condensing)
Avoid exposure to the following factors:
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down
hard)
Soot, vapour, dust and corrosive gases
Hazardous environments, flammable atmospheres
Store the temperature dry-well calibrator in its original
packaging in a location that fulfils the conditions listed above.

6.1 Voltage supply

DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct
danger to life.
Only ever use the supplied power cord (see
chapter 4.4 "Voltage supply").
Ensure that the correct operating voltage is
present when doing this.

6.2 Use at high temperatures

WARNING!
Fire hazard!
The calibrator is suitable for operating at high
temperatures with the consequent danger of fire.
Keep inflammable material away.
Do not pour any liquids into the interior of the
block.
EN