Remote control (CN591) mode switch
SW 500
No. 4
No. 5
No. 6
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
10
Functions
Do not use the CN591 remote control
ON/OFF Prohibited/Allowed mode 1
ON/OFF Prohibited/Allowed mode 2
(level input)
ON/OFF Prohibited/Allowed mode 3
(pulse input)
Coin timer mode 1 (for a no-voltage
contact point a)
Coin timer mode 2 (for a no-voltage
contact point b)
Cooling-Heating/Temperature settings
mode 1 (3 temperature patterns)
Cooling-Heating/Temperature settings
mode 2 (8 temperature patterns)
Operating Details
Manual operations prohibited when CN591 No. 1 and No. 3 are closed, permitted
when open.
ON when CN591 No. 1 and No. 2 are closed, OFF when open.
(Cannot be operated from the remote control when manual operations are pro-
hibited. Only valid when operated from the CN591.)
ON when CN591 No. 1 and No. 2 are closed, OFF when open.
Manual operations prohibited when No. 1 and No. 3 are closed, permitted when
open.
(Cannot be operated from the remote control when manual operations are pro-
hibited. Only valid when operated from the CN591.)
ON when CN591 No. 1 and No. 2 are closed, OFF when No. 1 and No. 3 are closed.
Manual operations prohibited when No. 1 and No. 4 are closed, and permitted
when No. 1 and No. 5 are closed.
(Same as when they are open.)
Permitted and ON when CN591 No. 1 and No. 2 are closed, manual operations
prohibited and OFF when open.
(When permitted, the unit can be operated from the remote control.)
Manual operations prohibited and OFF when CN591 No. 1 and No. 2 are closed,
permitted and ON when open.
(When permitted, the unit can be operated from the remote control.)
ON when CN591 No. 1 and No. 2 are closed, OFF when open.
When No. 1 and No. 3 are closed
When No. 1 and No. 4 are closed
When No. 1 and No. 5 are closed
(When multiple switches No. 3, 4, and 5 are closed, the highest temperature will
be selected.)
Heating when No. 1 and No. 6 are closed, Cooling when open.
(Remote control operations are valid as always.)
ON when CN591 No. 1 and No. 2 are closed, OFF when open.
No. 1 and No. 3
No. 4
Open
Open
Closed
Open
Open
Closed
Closed
Closed
Open
Open
Closed
Open
Open
Closed
Closed
Closed
Heating when No. 1 and No. 6 are closed, Cooling when open.
(Remote control operations are valid as always.)
20 °C
24 °C
28 °C
No. 5
Temperature settings
Open
16 °C
Open
18 °C
Open
20 °C
Open
22 °C
Closed
24 °C
Closed
26 °C
Closed
28 °C
Closed
30 °C