Electrical Work - Mitsubishi Electric PUZ-ZM-HA Para El Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58

6. Electrical work

6.1. Outdoor unit (Fig. 6-1, Fig. 6-2)
1 Remove the service panel.
2 Wire the cables referring to the Fig. 6-1 and the Fig. 6-2.
S1
S2
S3
B
L N
S1
S2
S3
D
For Power
For Power
D
B
E
12
A
A Indoor unit
B Outdoor unit
C Remote controller
C
D Main switch (Breaker)
E Earth
A
A
C
E
Fig. 6-1
ZM35, 50
F
J
I
ZM60, 71
F
A
E
H
F Terminal block
G Indoor/Outdoor connection terminal block (S1, S2, S3)
H Service panel
I Clamp
* Clamp the cables so that they do not contact the center of the service panel or the gas valve.
J Earth terminal
Note :
If the protective sheet for the electrical box is removed during servicing, be sure to
reinstall it.
Caution:
Be sure to install N-Line. Without N-Line, it could cause damage to unit.
ZM35, 50
J
H
ZM60, 71
G
J
L N
I
Fig. 6-2
J
S1 S2 S3
J
Tabla de contenido
loading

Este manual también es adecuado para:

Puz-zm-ha-erPuz-zm-kaPuz-zm-ka-er

Tabla de contenido