Operation (E); Ro Bc14/36 Charger, Ro Bp18/2 And Ro Bp18/4 Battery (F) - Rothenberger ROMAX 4000 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
After changing the press jaw it is essential to ensure that, once engaged, the crimping jaw
matches the profile being moulded and the nominal width of the fitting being moulded. A visual
inspection must be carried out in order to determine that the press jaw is fully closed at the end
of the press cycle.
3.7
Operation
Use only system-compatible press fittings and press jaws designed for them. The nominal size
of the press jaw must be identical with the nominal size of the press fitting.
When inserting the pipe / press fitting system, there is a risk of crush injuries for the
fingers or other body parts near the press jaw!
 Push the press fitting on to the pipe (1). Pull the press jaw apart and insert the pipe with the
press fitting at right angles.
There must be no foreign bodies between the press contour and the fitting. If you fail to
ensure this, the pressing process will not produce a perfect joint!
 Press the ON button until the pressing process has been completed (2). The motor cut out
indicates the end of the moulding cycle.
 Push the press jaw apart and take the machine off the joint (3).
Do not start the machine while the piston retracts or the emergency shutdown is pressed!
3.8
RO BC14/36 Charger, RO BP18/2 and RO BP18/4 battery
Overview:
1
Battery pack
2
Sliding seat
3
Operation display
Start of operation
Before plugging in, check to see that the rated mains voltage and mains fre-
quency, as specified on the rating label, match your power supply.
Devices such as this one, which generate direct current, may have an effect on basic residual-
current circuit breakers. Use type F or better, with a release current of max. 30 mA.
Before commissioning the charger, ensure that the air slots are free. Minimum
distance to other objects is 5 cm.
Self-test:
 Insert mains supply plug.
The warning display (4) and the operating indicator (3) light up one after the other for approx. 1
second and the installed fan runs for approx. 5 seconds.
Battery pack:
Charge the battery pack before use (1).
If performance diminishes, recharge the battery pack.
The ideal storage temperature is between 10°C and 30°C. The permissible storage temperature
is between 0°C and 50°C.
"Li-Power" li-ion battery packs have a capacity and signal indicator: (6)
 Press the button (5), the LEDs indicate the charge level.
If one LED is flashing, the battery pack is almost flat and must be recharged.
Handling
Charging battery pack:
 Push the battery pack completely to the stop on the sliding seat (2).
The operating indicator (3) flashes.
4
Warning display
5
Capacity indicator button
6
Capacity and signal indicator
ENGLISH
(E)
(F)
19
Tabla de contenido
loading

Tabla de contenido