13. ERROR MESSAGES AND POSSIBLE SOLUTIONS
Error Message Display/Problem
Please insert the SD card!
Error: Old MMC card!
Initialise SD card!
Overvoltage > 1000 V! Switch off!
Check the measuring setup!
Overcurrent > 15A Switch off!
Internal error!
Error: Communication of measurement
Error: Open-circuit voltage (xxV) < 5 V!
Error: Irradiation too low
Error: Irradiation outside tolerance
STC impossible
TRI-SEN data missing!
Measuring curve must later be adjusted
manually.
No data for measuring curve
Data synchronisation failed
Measurement not found
No data or files could be read!
Verification failed!
Error: Battery voltage too low/
Device fails to activate
No firmware file found!
Firmware file could not be opened!
Error formatting!
Module to be tested missing
from module database
Cause
There is no SD card inserted into the measuring device TRI-KA.
Inserted SD card is corrupted and cannot be read.
A MMC card has been inserted into the TRI-KA.
Measuring cables receive a voltage higher than 1000 V!
Measuring cables receive a current higher than 15A!
Internal error in measuring device
Internal error in measuring device
Measuring cables receive a voltage lower than 5 V.
Irradiation measured by the TRI-SEN is lower than the set minimum
irradiation in the monitoring values for the output measurement
in the TRI-KA.
Irradiation measured by the TRI-SEN changes during the characteristics
analysis beyond the set tolerance value in the monitoring values for the
output measurement.
Type of the tested module is a thin-layer module.
Characteristics analysis was performed without radio connection between
TRI-SEN and TRI-KA.
The measured TRI-SEN data must later be synchronised with the TRI-KA.
TRI-KA cannot find measured data for the respective measurement during
the later synchronisation of the TRI-SEN data.
TRI-SEN has been deactivated before synchronisation.
The later synchronisation of measured TRI-KA and TRI-SEN data has failed.
During synchronisation, no measured TRI-SEN data could be allocated
to a TRI-KA measurement.
TRI-KA measurement file was deleted before synchronisation.
TRI-KA cannot load saved measurement file.
Measurement file corrupted
Data format of measurement file does not correspond to data format
of measuring device.
Measurement file was manually manipulated!
Battery capacity of LiPo battery too low
Could not perform firmware update. File could not be found.
Firmware file cannot be opened.
File corrupted
Incorrect type of memory card inserted into TRI-KA
SD card cannot be formatted.
Module does not exist in module database.