VACUUM PACKAGING MACHINE

Dimensions
Voltage
Welding bar
Pump
Bodywork
Weight
Vacuum creation
Sealing
Automatic cooling/Timer system
Control panel
Air re-entry
Start up
Vacuum creation
1
2
3
4
1. ON-OFF BUTTON
2. MODE KEY
3. SET KEY
4. MULTIFUNCTION INCREASE KEY (+)
5. MULTIFUNCTION DECREASE KEY (-)
6. SEAL PUMP KEY
CONDITIONS OF USE
The machine specifically is designed for the vacuum packing of food.
Applications
other than
those
recommended.
Improper or different use will void the warranty, may damage
components
and
consequently
envisaged machine functions.
IMPORTANT
·
Read the instructions before using the machine. Keep them
with the machine for future reference.
·
Keep the working environment tidy and clean.
·
Keep children away from the machine working area.
·
Use the vacuum packer for the purpose for which it was
designed only. Applications other than vacuum packing will
void the warranty and may be dangerous.
·
Do not overload the machine. Look after the machine carefully.
·
Place the device on a stable, safe surface. Dropping the
machine may cause severe damage.
·
Do not pack liquid food or substances inside bags to avoid
danger and prevent damaging the device beyond repair.
·
To pack foods with a large amount of liquid inside, eliminate
the excess fluid carefully with a cloth or food-safe paper before
packing; alternatively use a rigid container or lids for jars made
available by the manufacturer in different sizes..
·
Make sure there are no foreign objects (knives. blades, tools,
etc.) near the sealing bar before starting each process.
·
Always stop the machine, turn it off and unplug the power cord
before starting any operation (e.g. cleaning, checking packed
products, adjustments, assembly, etc.) to prevent unexpected
start-up. This precaution must also be adopted when the
machine is not working. Check that mains voltage and
frequency correspond to those shown on the machine and that
the plug is proportioned to the drawn current.
·
Only use original spare parts and accessories.
·
This is an electrical device. Never submerge the machine in
water.
510x295x180 h mm
220/240 volt 50/60 Hz
2x430 mm
self lubricating 32 l/min
stainless steel
12 kg
with sensor
Electronic
9 variable settings
digital LCD display
5 languages
with electro-valve
with micro switch
bags, containers, pots
5
6
specifically envisaged are
impede
performance
of
·
Never expose the machine to jets of water.
·
Never pull the cord to unplug the machine.
·
The power socket you use must be connected to earth and
your electrical system must be provided with an automatic
circuit breaker.
·
Entrust replacements of the power cord and electrical repairs
to specialised personnel only.
The machine must be installed and used by only one operator at a
time. It is not designed to be operated by more than one person at
a time.
The machine consists essentially of a main structure entirely made
of AISI 430 steel, inside which the electrical panel and the vacuum
generating working unit are arranged. No interventions are required
on the working unit (except for supplementary maintenance which
should be entrusted to the manufacturer). It is recommended not to
intervene in any way except for the specific operations described in
this instruction manual.
The sealing bar, which seals the bag at the end of the process is
arranged outside the structure on the lower front of the machine. A
gasket) delimits the fixed part of the decompression chamber,
where the bag opening is placed for packaging.
The mobile part of the decompression chamber is fitted to a mobile
lid connected to the structure by two hinges to be pulled on the bag
opening during the process.
·
Remove the machine from its packaging, place it on a working
surface making sure it is stable.
·
It is important that the four feet of the device rest on the
surface to ensure that the mobile lid and the lower part of the
machine closes properly. This will guarantee a correct air
suction.
·
It is advisable to keep the machine packaging in case you need
to deliver it to have it repaired.
·
Clean the machine carefully before starting it up.
·
To clean the external body, wipe it with a damp cloth and then
with a dry cloth. To clean the control panel use a dry cloth
only. Never use acid or caustic products.
not
·
Insert the plug in the socket and press "on-off button" (1) for
2 secs.
·
After a brief switch-on process the machine is ready to work in
the
the mode and with the sealing time selected the last time it
was used.
·
Choose the required operating mode pressing the "mode key"
(2). See paragraph OPERATING MODES .
Your vacuum sealer is able to talk with you in your language.
To set the language on the display (10), proceed as follows:
·
Switch on the machine pressing the 'on-off button" (1) for 2
secs.
·
On the display, a greeting will appear for 3 secs. Within the 3
secs. press the "SET key" (3). If the operation is not completed
in 3 secs. switch off the machine and start again.
·
Choose your language with the "increase multifunction key
(+)" and the "decrease multifunction key (-)", according to the
table below:
Lang.
Lang.
Lang.
Lang.
Lang.
·
To view the chosen language, press the 'SET key" (3) for 2
sec., or wait for a few seconds (the machine will automatically
set the language).
USE AND MAINTENANCE INSTRUCTIONS
IMPORTANT
DESCRIPTION
STARTING UP
LANGUAGE SETTING
IDENTIFICATION
0
1
2
3
4
LANGUAGE
Dutch
English
Spanish
German
French
Tabla de contenido