Data On Serial Plate; Trouble Shooting - Nussbaum TC 110 PRO Manual De Instrucciones

Ocultar thumbs Ver también para TC 110 PRO:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

(1*/,6+ ‡ ,QVWUXFWLRQV PDQXDO
The manufacturer's Serial plate is fixed on the back of the machine.
If gives the following information:
1-
Manufacturer information
2-
Model
3-
Serial number
4-
Phases
5-
Voltage requirements
6-
Frequency
7-
Rated draw
8-
Power absorbed
9-
Working pressure
10-
Weight
11-
Year
PROBLEM
When the pedal (1, Fig. H) is pressed the table top does not turn.
CAUSES
1) The power plug is not inserted.
2) No power from the mains electric supply.
REMEDIES
1) Insert the plug correctly in its socket.
2) Reset the mains electric supply.
PROBLEM
When the table top (5, Fig. H) or the bead breaker (3, Fig.
H) pedal is pressed, nothing happens.
CAUSES
1) No compressed air supply to the system.
2) Compressed air hose is crimped or crushed.
REMEDIES
1) Check and correct the compressed air supply source.
2) Check and correct any hose defects. Replace hose if damaged.
WARNING:
If, inspite of the above mentioned
indications the tyre changer doesn't
work properly, do not use it and call for
technical assistance.