CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and
a light switch to control cooking area lights.
Models with mechanical control panel
HHBS 6.5F AM X - HHBS 9.5F AM X - HHF 6.4 F AM X - HHF 6.4 F AM K
HHF 9.4 F AM X - HHF 9.5 F AM X - HHGC 9.4F AM X - HHGC 6.4F AM X
T1. ON/OFF light switch
T2. Speed 1/OFF switch
T3. 2-speed selection
T4. 3-speed selection
Models with Soft Button panel + LCD Display
HHBS 6.7F LL X - HHBS 9.7F LLI X - HHF 6.7F LL X
T1. Button ON/OFF suction motor
T2. Selection button for medium, high and intensive operating suction
speed (power).
Note: Intensive suction speed (power) intensiva (LED L1 flashing) lasts for
approximately 5 minutes, then the medium suction speed (power) is
automatically set.
T3. Selection button for 'silent' suction speed (power)
T4. Button ON/OFF lighting
L1. Status icon suction speeds (powers)
L2. Status icon saturation indicator for grease filter
L3. Status icon low (silent) suction speed (power)
L4. Status icon saturation indicator charcoal filter
L5. Status icon lighting
Reset filter saturation indicator
After performing maintenance of the filter, press and hold button T3, the icon
indicating saturation will switch off. Repeat the operation if both icons indicating
saturation (grease and charcoal) are on.
Activation of the icon for charcoal filter saturation
The icon for charcoal filter saturation is normally disabled. To activate it,
proceed as follows:
With the hood off, press and hold for a long time and simultaneously T1 and
T3: L4 flashes at first then it switches on with steady light to indicate
successful activation.
Disabling the icon for charcoal filter saturation: repeat the above
operation, L4 switches on with steady light then flashes and in the end
switches off to indicate successful disabling.
Automatic operation at high temperature
The hood is fitted with a sensor that detects the temperature. When this
becomes too high, the sensor automatically activates the medium suction speed
(power). The hood switches off when the temperature detected by the sensor
has lowered significantly.
22
Models with Soft Button panel + Delay OFF
RHHF 9.7F LB X - RHHBS 9.7F LB X - RHHGC 9.7F LB X
RHHC 9.7F LB X
T1. Button ON/OFF suction motor
T2. Selection button operating suction speed (power)
Note: The intensive suction speed (power) (LED L3 flashing) lasts for
approximately 5 minutes, then the medium suction speed (power) is
automatically set (LED L2 on)
T3. Button ON/OFF lighting
T4. Automatic shutdown button:
Note: press this button to set the automatic shutdown after:
Low suction speed (power): 20 minutes
Medium suction speed (power): 15 minutes
High suction speed (power): 10 minutes
Intensive suction speed (power): 5 minutes
L1. LED low suction speed (power)
L2. LED medium suction speed (power)
L3. LED high suction speed (power)
L4 LED intensive suction speed (power) - timed (5 min.).
L5 LED for filter saturation:
flashing: carry out maintenance of the charcoal filter;
on: carry out maintenance of grease filters.
L1+L2+L3 flashing in sequence: automatic operation at high temperature (see
related section)
Reset filter saturation
After carrying out filter maintenance, press and hold button T1, LED L5 switches
off.
Activation of the LED for charcoal filter saturation
The LED for charcoal filter saturation is normally disabled. To activate it,
proceed as follows:
With the hood off, press and hold for a long time and simultaneously T1 and
T4: L1 flashes at first, then L2 as well, to indicate successful activation.
Disabling the LED for charcoal filter saturation: repeat the above
operation, first L1 and L2 start flashing then only L1 to indicate successful
disabling.
Automatic operation at high temperature
The hood is fitted with a sensor that detects the temperature. When this
becomes too high, the sensor automatically switches on the medium suction
speed (power). The hood switches off when the temperature detected by the
sensor has lowered significantly.