Stihl RMA 443 Manual De Instrucciones página 64

Ocultar thumbs Ver también para RMA 443:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 153
Fault:
Excessive vibration during operation
Possible cause:
– Blade fastening screw is loose
– Blade is not balanced
Remedy:
– Tighten blade fastening screw (
– Re-sharpen (balance) or replace blade
(
13.8)
Fault:
Poor cut, lawn turning yellow
Possible cause:
– Mowing blade is blunt or worn,
– Rate of feed is too high in relation to the
cutting height
Remedy:
– Re-sharpen or replace mowing blade
(
13.8)
– Reduce rate of feed and/or select
correct cutting height (
Fault:
Problems switching machine on or
deteriorating motor power.
Possible cause:
– Battery discharged
– Mowing grass that is too long or too wet
– Mower housing is blocked
– Mowing blades are blunt or worn
Remedy:
– Recharge battery (
8.4)
– Adapt cutting height and mowing speed
to mowing conditions (
– Clean mower housing (
– Re-sharpen or replace mowing blade
(
13.8)
62
Fault:
Discharge chute blocked
Possible cause:
– Mowing blade is worn
– Mowing grass which is too long or too
wet
13.7)
Remedy:
– Replace mowing blade (
– Adapt cutting height and mowing speed
to mowing conditions (
Fault:
Operating time too short
Possible cause:
– Battery not fully charged
– Mowing grass that is too long or too wet
– Mower housing is blocked
– Mowing blades are blunt or worn
– Battery has exceeded service life
Remedy:
9.6)
– Recharge battery (
– Adapt cutting height and mowing speed
to mowing conditions (
– Clean mower housing (
– Re-sharpen or replace mowing blade
(
13.8)
– Replace battery ( )
Fault:
Battery gets stuck when inserting into
battery compartment
Possible cause:
– Guides or electric contacts in battery
compartment dirty
9.6)
13.2)
Remedy:
– Clean guides and/or electric contacts in
battery compartment (
Fault:
Battery is not charged although the green
LED on the charger illuminates green
Possible cause:
– Battery too cold or overheated (one red
LED illuminates on battery)
Remedy:
13.8)
– Warm up or cool down the battery
(
9.6)
dry place at a temperature of between
+5°C and +40°C.
Fault:
Charging fails to start after inserting
battery into charger
Possible cause:
– Battery too cold/too warm – 1 LED
illuminates red on battery
– No electrical contact between charger
and battery
– Charger power supply faulty
8.4)
Remedy:
9.6)
– Leave battery inserted in charger
13.2)
Charging starts automatically as soon
as permissible temperature range is
reached.
– Remove and re-insert battery (
– Connect charger to mains (
– Check mains power supply
– Check charger, replace if necessary
( )
Fault:
Battery is not charged, no LED illuminates
Possible cause:
– No electrical contact between charger
and battery
13.2)
8.4). Store the charger in a closed,
0478 131 9940 B - EN
8.3)
8.2)
Tabla de contenido
loading

Este manual también es adecuado para:

Rma 443 cRma 443 tcRma 448 tcRma 443 pcRma 448 pc

Tabla de contenido