Cleaning the coarse filter through cleaning valve
In order to get maximum suction capacity is the dust extractor equipped with a cleaning valve which
effortlessly cleans the coarse filter.
1. Start the machine
Start button is
set to "1"
(Machine ON)
N.B. Clean the filter every time you start and before you stop the machine.
Replacing the coarse filter
1. Open the cyclone lid
Replacing the HEPA13 filter
1. Remove lid
Warning
Health impairing dust can be spread when cleaning the coarse filter and during filter and bag
replacement. Accordingly, the user should wear tight fitting clothing, protective glasses, protective
gloves and a breathing mask conforming to protection class P2.
2. Block the suction hose by the
work place. Wait about 7-10 sec.
while the machine builds up a
vacuum.
Repeat the whole process 3 times.
2. Remove the lid
2. Loosen the nuts
3. Press the filter cleaning valve
hard
3. Replace the coarse filter
3. Remove lid
7
4. Replace the