Check Detergent Siphoning Tube
Examine the filter on detergent tube (if equipped) and clean
if clogged. The tube should fit tightly on the barbed fitting.
Examine the tube for leaks or tears. Replacethe filter or tube
if either is damaged.
Detergent Siphoning Check Bail
Occasionally check ball in detergent siphoning system may
become stuck from storage, dried soap, or minerals in water.
The check ball can be freed by performing the following:
NOTICE Before performing this procedure, be sure you are
wearing safety goggles as described below.
WARNENG Risk of eye injury.
Spray could splash back or propel objects
resulting in serious injury'.
o Always wear indirect vented (chembaI splash) safety goggbs
marked to comply with ANSI Z87.1 when using or in vicinity of
this equipment.
o NEVERsubstitute safety ghsses or dry-condition goggbs for
indirect vented safety goggbs.
1.
Shut OFF(0) engine and turn off water supply.
2.
ALWAYS point spray gun in a safe direction, press red
button and squeezespray gun trigger to releaseretained
high water pressure.
WARNING The high pressure stream of water that
this equipment produces could cut through skin
and its underlying tissues, resulting in serious
injury and possible amputation.
Spray gun traps high water pressure, even when engine is
stopped and water is disconnected, which could result in
serious injury.
o Keephigh pressure hoseconnected to pumpand spraygun
whilesystemis pressurized,
o ALWAYSpointspraygun in safedirection,pressredbutton
andsqueeze sprayguntriggerto release highpressure, e very
time you stop engine,
.
4.
Removedetergent siphoning hose from barbed fitting
on pump.
Using a firm, blunt object 7/64" in diameter or smaller,
by at bast 1" long, such as an Allen wrench, slowly
insert the object into the barbed fitting until you meet
resistance.This resistance is the check ball.
5.
Slowly push down until you feel the ball move slightly,
push no more than 1/8". Slight pressure may be
required to free the ball.
6.
Repeatsteps 4 and 5 if necessary,.
7.
Reinstall detergent siphoning hose onto barb fitting.
8.
Treat with PumpSaveras described in Protecting the
Pump during storage to prevent reoccurrence.
Check Spray Gun
Examinehose connectionto spray gun and make sure it is
secure.Test trigger by pressing it and making sure it springs
back into placewhen you releaseit. Do not depress red button
and test trigger. You should not be ableto press trigger.
Replacespray gun immediately if it fails any of these tests.
19