Error 3
When a Start command is given and the gate does not open and
Err3
the display shows
It means that the photocell test failed.
1. Be sure that no obstacle interrupted the photocell beam when
the Start command was given.
2. Be sure that photocells, as enabled by their relevant menus,
have been installed actually.
3. If you have photocells 2, be sure that Fot2 menu item is on
CF.Ch
.
4. Be sure that photocells are powered and working; when you
interrupt their beam, you should hear the relay tripping.
5. Ensure the photocells are connected correctly, as shown in the
chapter 5.5
Error 4
When a Start command is given and the gate does not open (or
does a partial opening) and the display shows
It means that the end of stroke is damaged or that the wiring that
connects the sensor to the control unit is broken.
• Change the end of stroke sensor or the broken wiring. If the
error persists send the control unit to V2 S.p.A. for repair.
• If limit switches have not been connected, check that the
FC.En
function is set to no.
Error 5
Once given a start control, the gate does not open and the display
Err5
shows
It means that the test of the safety edges failed.
Check that the menu of the test of safety edges (
been set correctly.
Check that the safety edges enabled from the menu are installed.
Error 7
Err7
The display shows
This indicates an error in the encoders' operation.
There are three possible causes:
1. With the encoders connected, even if they are not enabled, for
a few instants after movement of a gate panel. This means that
the connection to the encoder for that gate panel is reversed.
Exchange terminal K1 with K2, or K3 with K4
2. With the encoders enabled, once a START command is
received: This means that the encoders have not been
initialized. For the encoders to operate correctly, the
self-learning procedure must be performed.
3. With the encoders enabled and initialized, a few seconds after
movement begins: This means that an encoder is NOT correctly
operating. Encoder malfunction or broken connection.
PLEASE NOTE: Check the connection is in line with the motor
instructions
Error 8
When executing a self-learning function the control is refused and
the display shows
It means that the setting of the control unit is not compatible with
the requested function.
In order to carry out self-learning, the Start inputs must be
enabled in standard mode (
ADI interface must be disabled (
To survey the currents of the motor it is also necessary that the
length of the opening and closure are at least of 7,5 second.
Error 9
When you are trying to change the control unit setups and the the
display shows
It means that programming was locked by means of the
programming lock key CL1+ (code 161213).
To change the settings it is necessary to insert in the connector of
the ADI interface the same key used to activate the programming
Err4
lock, and unlock the device.
Error 10
When a start command is given, the gate does not open and the
display shows the message
This means that the ADI module function test failed.
Co.tE
) have
- 44 -
Err8
Strt
menu set to
i.Adi
menu set to
Err9
Er 10
StAn
) and the
no
).