Heath Zenith BL-5511 Manual De Instrucciones página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor requires about 1
before it will detect motion. When first turned
on, wait about 1
❒ Set the ON-TIME control to the TEST position.
ON-TIME
10
TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum
Range
The control is most sensitive to motion across it.
Motion
Sensor
Least Sensitive
598-1324-01
1
/
minutes to calibrate
2
/
minutes.
1
2
50 ft.
(15.2 m)
Maximum
Coverage Angle
Motion
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor to aim.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (25 mm) away from
the lamps.
❒ Secure the sensor head into
position by tightening the
clamp screw. Do not over-
tighten the screw.
❒ Set the ON-TIME control to 10
minutes.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 50 ft. (15.2 m); [varies with
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 10 minutes
Sensitivity . . . . . . . . . . Adjustable
110°
Replacement lamp . . . . T 150W (or less) halogen 120
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
3
Clamp
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature]
tungsten
MODE
VAC
Tabla de contenido
loading

Tabla de contenido